Professional TV equipment design, development and production.

 
     
   

Products by family

 
 

 

Products by topic

Main / Encoders, transcoders / PENC-3338

PENC-3338 series SDI-to-PAL/YC/YUV/RGB/SDI monitoring encoder

PROFLEX™ PENC-3338 series monitoring encoder provides the capability to monitor the D1 270Mbps SDI input signal by means of converting it into the PAL/YC/YUV/RGB/SDI format with the bargraph OSD of four-channel audio level metering. PENC-3338 occupies one slot in the PROFLEX rack.

Features

  • automatic cable equalizer
  • reclocked/reshaped SDI output
  • EDH packets and embedded audio presence indication
  • EDH status (min/hour) display
  • SDI signal loss indication
  • deembeddable audio group selection (for bargraph OSD)
  • dBu/dBFS audio level scale selection
    • quasi-analog dBu
    • dBFS corresponds to +18 dBu
  • audio level OSD ON/OFF and placement controls
  • monitor SDI output with the bargraph audio level meter OSD
  • monitor PAL/YC/YPrPb/RGB output with the bargraph audio level meter OSD

Technical specifications

  • Input
    • SDI

      Standard compliance

      ITU-R BT.656

      Connectors, input impedance

      BNC, 75 Ohm

      Return loss

      >18dB at 270MHz

      Cable equalization

      up to 300 meters of 8281 or similar

  • Outputs
    • main SDI:
      number of outputs one, reclocked
      output signal standard as per input
      connectors BNC, 75 Ohm
      return loss better than 15 dB at 270 MHz
      signal amplitude 800mV±10%
    • SDI MONITOR
      number of outputs one, reclocked
      output signal standard as per input
      connectors BNC, 75 Ohm
      return loss better than 15 dB at 270 MHz
      signal amplitude 800mV±10%
    • analog outputs, BNC, 75 Ohm, (user selectable):
      • PAL/NTSC
      • YC
      • YPrPb
      • RGB

PENC-3338 rear panel

General description

An input SDI signal is equalised and reclocked. A serial stream is decoded into a 10-bits 4:2:2 which is processed to extract the video and audio, EDH status is detected. The audio signal from a user-selected group is then analyzed in the four-channel level meter. The video signal is provided at the output in SDI/PAL(NTSC)/YC/YUV/RGB formats with the bargraph audio level OSD overlayed.

Controls and indicators

PENC-3338 frontal panel

The MODE button toggles through all the modes, the UP and DOWN buttons edit them.

  • OUT STD – output signal standard selection:
    • CS – two composite PAL/NTSC and one component C
    • YC – one composite PAL/NTSC and one component YC
    • Yu – one component YPrPb
    • rG – one component RGB
  • GROUP SEL – audio group selection for deembedding, (Ø1, Ø2, Ø3, Ø4). The "12" and "34" LEDs indicate the audio group presence in the input SDIembedded signal
  • VU OFF – audio level meter OSD enable/disable
  • DBU/DBFS – audio level meter scale selection:
    • dBU, (quasi-analog, 0dBU corresponds to 0,775VRMS), shown as "db"
    • dBFS (EBU R68, 0dBFS corresponds to +18 dBu, shown as "FS"
  • VU POS – audio level meter OSD horizontal position selection

Indicators:

  • LOSS – lit when the input SDI signal loss is detected
  • EDH DET – lit when the EDH packets are detected in the input SDI
  • EDH MIN/HOUR – lit if two or more EDH errors were detected within one hour/minute interval
  • AUD DET – lit when embedded audio packets are detected in the input SDI
  • 12/34 – lit when embedded audio packets are detected in the selected group
  • 625 – lit when the input signal standard is 625/50
  • 525 – lit when the input signal standard is 525/60

The remote control and management from a PC

All the “PROFLEX” modules are remote controllable from a PC. This facility is available if a rack is fitted with a CPU module (ordered separately).


2019 PROFITT Ltd