Main / "PROFLINK" modular system / PLK-RC-954
PLK-RC-954 single-channel autoconfigurable reclocker module |
"PROFLINK"™ PLK-RC-954 single-channel reclocker module is auto-configurable by an inserted SFP as an:
- optical RX with 2 reclocked electrical outputs
- optical TX with bypass reclocked electrical output
- optical transponder with 2 reclocked electrical outputs
SFP type: |
reclocker's electrical I/O configuration |
reclocker's functionality |
1-channel TX |
IN + OUT |
Reclocker with optical and electrical outputs (optical transmitter) |
1-channel RX |
OUT + OUT |
Optical receiver with two reclocked electrical outputs |
transceiver (RX+TX) |
OUT + OUT |
Optical regenerator/wavelength transponder with two reclocked electrical outputs |
The list of recommended 1-channel SFP modules (3Gbps, LC/UPC):
- 1-channel optical receivers:
- PRFT-30R-D, -24dBm ~ -3dBm input optical power
- PRFT-30R-DH, APD with -28dBm ~ -9dBm input optical power
- 1-channel optical transmitters:
- PRFT-1330T-10D, 1310nm FP laser, -5dBm ~ 0dBm output optical power
- PRFT-1330T-35D, 1310nm DFB laser, 0dBm ~ +3dBm output optical power
- PRFT-1530T-50D, 1550nm DFB laser, 0dBm ~ +3dBm output optical power
- PRFT-1630T-DX, CWDM DFB laser, 0dBm ~ +3dBm output optical power
- Optical transceivers:
- PRFT-1330-35D, 1310nm DFB laser, 0dBm ~ +3dBm output optical power; -18dBm ~ -3dBm input optical power
- PRFT-1330-50D, 1310nm DFB laser, 0dBm ~ +3dBm output optical power; APD with -28dBm ~ -9dBm input optical power
- PRFT-1530-50D, 1550nm DFB laser, 0dBm ~ +3dBm output optical power; -18dBm ~ -3dBm input optical power
- PRFT-1530-80D, 1550nm DFB laser, +3dBm ~ +7dBm output optical power; APD with -28dBm ~ -9dBm input optical power
- PRFT-1630-18DX, CWDM DFB laser, 0dBm ~ +3dBm output optical power; -18dBm ~ -3dBm input optical power
- PRFT-1630-28DX, CWDM DFB laser, 0dBm ~ +3dBm output optical power; APD with -28dBm ~ -9dBm input optical power
Indication of the operation mode
The reclocker module features the following LEDs on its' frontal edge:
- INP A - bicolor, if GREEN - the input signal is detected, if RED - no input signal present
- INP B - bicolor, on the 1-channel reclocker it never lits up
- TX - green, lit when reclocker operates as an Electric-to-Optic converter (optical transmitter)
- RX - green, lit when reclocker operates as an Optic-to-Electric converter (optical receiver)
When both RX and TX are lit - the reclocker operates as an optical transponder/regenerator
Connectors and indicators placement
The optical (LC) and electrical (HD BNC) connectors are located on the rear panel of the rack. The reclocker module indicator LEDs are located on module's frontal edge and are visible through the rack's removable frontal cover.
|