Main / Optical interfaces / PORC-3271SFP
PORC-3271SFP(A) series 4-channel TDM SDI/ASI optical receivers |
PORC-3271SFP(A) optical receivers provide the Time Division deMultiplexing of up to four SDI or ASI electrical streams received over a single optical wavelength signal. PORC-3271SFP(A) is intended to pair with the POTM-3251 optical transmitter. PORC-3271SFPA optical receiver is equipped with the APD (advanced photodiode) sensor SFP optical input, which provides higher optical sensitivity. PORC-3271SFP(A) module occupies one slot in the PROLFEX 1U/3U racks so that up to four receivers fit into a 1U rack and up to fifteen into a 3U rack.
Features
- SFP module as an optical input, providing a hot-swap capability and real-time monitoring of the optical input power
- APD SFP module (PORC-3271SFPA model only)
- up to four electrically multiplexed SDI/ASI streams over single optical fiber
- single optical signal in the WDM/CWDM band
- up to eight channels received using two optical DEMUX in WDM band
- up to sixty four channels received using sixteen optical DEMUX in CWDM band
- signal loss indication
- fault tolerant reception - loss of any signal within a multiplexed input stream does not affect the demultiplexation of the remaining signal(s)
- CRC status indication
Technical specifications
- Optical input
Number of inputs |
one, reclocked |
Optical sensitivity band |
1100~1650nm |
Maximum optical input power |
-3dBm |
Optical dynamic range |
PORC-3271SFP |
-24~-3dBm |
PORC-3271SFPA |
-29~-9dBm |
Data throughput |
1600Mb/s |
Optical connector type |
LC/UPC (SFP module) |
- Electrical output
Standard compliance |
SMPTE259M A,B,C,D; DVB-ASI, as per optical input |
Number of outputs |
4, reclocked |
Output impedance |
75 Ohm |
Return loss |
better than 18dB up to 270MHz |
Connector type , signal amplitude |
BNC, 800mV |
Signal rise/fall time, jitter |
700ps, 0.2UI |
Connector type |
BNC |
General description
PORC-3271SFP(A) simplified schematics:
An input optical signal of a single wavelength is detected and converted into electrical form. An electrical signal is deserialized by means of the TDM (TimeDivision deMultiplexing) and up to four SDI or DVB/ASI signals are recovered. These signals are available at electrical outputs.
PORC-3271SFP(A) rear panel:
Controls and indicators
PORC-3271SFP(A) frontal panel:
The controls
The MODE button toggles through all the modes, the UP button edits them. The CRC RESET button is used to reset the CRC status.
The indicators
- LINK LOCK – lit if there is valid input optical signal
- LINK LOSS – lit when an optical signal is lost
- CRC MIN – lit if there was a CRC error in the DVB-ASI stream during a last minute interval
- MON - lit when an output channel number is being assigned for monitor output (with the UP button)
- RxPwR - lit when an input optical power is being shown at the mail display (in dBm)
- CHANNEL 1...4 – lit if a valid SDI or DVB/ASI data stream is detected in a TDM slot
- LOSS 1...4 – lit when there is no data or a PLL cannot lock on a channel's stream
The remote control and management from a PC
All the “PROFLEX” modules are remote controllable from a PC. This facility is available if a rack is fitted with a CPU module (ordered separately). |