Main / Optical interfaces / PORC-3271SFP 
    
      | PORC-3271SFP(A) series 4-channel TDM SDI/ASI optical receivers |  PORC-3271SFP(A) optical receivers provide the Time Division deMultiplexing of up to four SDI or ASI electrical streams received over a single optical wavelength signal. PORC-3271SFP(A) is intended to pair with the POTM-3251 optical transmitter. PORC-3271SFPA optical receiver is equipped with the APD (advanced photodiode) sensor SFP optical input, which provides higher optical sensitivity. PORC-3271SFP(A) module occupies one slot in the PROLFEX 1U/3U racks so that up to four receivers fit into a 1U rack and up to fifteen into a 3U rack. Features 
    SFP module as an optical input, providing a hot-swap capability and real-time monitoring of the optical input powerAPD SFP module (PORC-3271SFPA model only)up to four electrically multiplexed SDI/ASI streams over single optical fibersingle optical signal in the WDM/CWDM band up to eight channels received using two optical DEMUX in WDM bandup to sixty four channels received using sixteen optical DEMUX in CWDM bandsignal loss indicationfault tolerant reception - loss of any signal within a multiplexed input stream does not affect the demultiplexation of the remaining signal(s)CRC status indication Technical specifications 
  Optical input
 
  
    | Number of inputs | one, reclocked |  
    | Optical sensitivity band | 1100~1650nm |  
    | Maximum optical input power | -3dBm |  
    | Optical dynamic range | PORC-3271SFP | -24~-3dBm |  
    | PORC-3271SFPA | -29~-9dBm |  
    | Data throughput | 1600Mb/s |  
    | Optical connector type | LC/UPC (SFP module) | Electrical output
 
  
    | Standard compliance | SMPTE259M A,B,C,D; DVB-ASI, as per optical input |  
    | Number of outputs | 4, reclocked |  
    | Output impedance | 75 Ohm |  
    | Return loss | better than 18dB up to 270MHz |  
    | Connector type , signal amplitude | BNC, 800mV |  
    | Signal rise/fall time, jitter | 700ps, 0.2UI |  
    | Connector type | BNC |  General descriptionPORC-3271SFP(A) simplified schematics: 
 An input optical signal of a single wavelength is detected and converted into electrical form. An electrical signal is deserialized by means of the TDM (TimeDivision deMultiplexing) and up to four SDI or DVB/ASI signals are recovered. These signals are available at electrical outputs. PORC-3271SFP(A) rear panel: 
 Controls and indicators PORC-3271SFP(A) frontal panel:  
 The controls The MODE button toggles through all the modes, the UP button edits them. The CRC RESET button is used to reset the CRC status.
 The indicators 
  LINK LOCK – lit if there is valid input optical signalLINK LOSS – lit when an optical signal is lostCRC MIN – lit if there was a CRC error in the DVB-ASI stream during a last minute intervalMON - lit when an output channel number is being assigned for monitor output (with the UP button)RxPwR - lit when an input optical power is being shown at the mail display (in dBm)CHANNEL 1...4 – lit if a valid SDI or DVB/ASI data stream is detected in a TDM slotLOSS 1...4 – lit when there is no data or a PLL cannot lock on a channel's stream The remote control and management from a PC All the “PROFLEX” modules are remote controllable from a PC. This facility is available if a rack is fitted with a CPU module (ordered separately). |